Radiator Thermostat A8

Product Details
Customization: Available
Temperature: High Temperature
Standard: Nonstandard
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Export Year
2019-04-12
OEM/ODM Availability
Yes
  • Radiator Thermostat A8
  • Radiator Thermostat A8
  • Radiator Thermostat A8
  • Radiator Thermostat A8
  • Radiator Thermostat A8
  • Radiator Thermostat A8
Find Similar Products

Basic Info.

Model NO.
A8
Connection Mode
Internal Thread
Power
Electric Power
Material
Plastic
Type
Balance Valve
Transport Package
Carton
Trademark
AIBOHOME
Origin
China
HS Code
848180
Production Capacity
8000000

Product Description

 

Radiator thermostat A8

Function

With the Radiator Thermostat model A8,you can conveniently regulate the room temperature. Thanks to pre-programmed or individually tailored heating and cooling phases the desired temperat*ure can be comfortably adjusted. The device moves a

valve to control the flow of heat to the radiator. The radiator thermostat fits to all common radiator valve and is easy to mount -

without having to drain any water or intervene in the heating system. The additional boost function enables quick, short-term

radiator heating by opening the valve for 5 minutes. This immediately bring a comfortable warmth to the room. This

programmable radiator thermostat is used to control the conventional radiator valves.

* Only operate the device in inside rooms and avoid the influence of moisture, dust and sunlight or external heat radiation.

* Using the radiator thermostat for any purpose other than that described in this operating manual does not fall within the scope

of intended use and shall invalidate any warranty or liability. The device is not a toy; do not allow children to play with it.

* Do not open the device: it does not contain any components that need to be serviced by user.

* In the event of an error, please return it to our

service department.

A - Union nut for fitting on the heating valve 

B - 87 segments LCD display

C - Operation buttons

D - Battery Cover

E - 2x1.5 V LR6/Mignon/AA inside

Radiator Thermostat A8

 

 

Inserting (replacing) batteries

In the initial state, the batteries are already inserted. Simplyremove the insulation strip.

To replace the batteries, please proceed as follows:

* Press the battery compartment cover on both side with your fingers and remove the cover by pushing it downwards.

* Insert 2 new LR6 (mignon/AA) batteries in the battery compartment, making sure they are the right way round.

* Reattach the battery compartment cover and latch it into place. The service life of new alkaline batteries is approximately 3 years.

A battery symbol ( ) on the display indicates that the batteries need to replaced. After removing the empty batteries, wait approx

1 minute before inserting the new ones.

This device does not support operation with rechargeable batteries. Never recharge standard batteries. Doing so will

present a risk of explosion. Do not throw the batteries into a fire. Do not short-circuit batteries.

 

Installation on the radiator

 

The radiator thermostat is easy to install and can be done without draining heating water or intervening in the heating system. No

special tools are required, nor does the heating have to be switched off.The union nut attached to the radiator thermostat can

be used universally and without accessories for valves of the most popular manufacturers with a thread size of M30 x 1.5 mm.

By means of the adapter in the delivery, the device can be installed on the radiator valve of type Dan foss RA.

The provided adapter is required for installation on Dan foss valves. The Dan foss valve bodies have elongated notches around

their circumference, which also ensure that the adapter is properly seated when it snaps on.

*   If required, place the provided support ring into the flange before mounting the radiator thermostat.

*   During installation, please ensure that the pings inside the adapter are lined up with the notches on the valve. Ensure that the

adapter is properly clipped on.

* Take care during installation that you do not trap your fingers between the two halves of adapter!

The first time you install the thermostat A8, it will automatically do an action, valve stroke identification, which does not require

manual intervention.

 

1. Open the battery cover, install the battery, and display theversion  A8.01 

2. The stem automatically retreats to its maximum position, LCD display INS 

3. Connect the A8 to the valve, tighten the joint nut and press any key.

4. The thermostat automatically matches the valve stroke, LCD display ADA

5.The matching completes the normal working state.

 

Operation and Display

 

 

Radiator Thermostat A8

A - Bar chart of programmed heating phases

B - Comfort temperature, factory set 21

C - Open-window function

D - Eco temperature, factory set 17

E - Auto mode

F - Manual mode

G - Holiday function

H - Display of temperature,time and date, menu options,functions

I - Measuring temperature value

J - Setting temperature value

K - Stroke percent index

L - Low battery symbol

M - Week day Open-window function

Radiator Thermostat A8

 

Radiator Thermostat A8


DOWN button

 

In normal operation:

* Click on the selection of the run mode

* Double-click: check the time

* Click 3 continuously: check the setting temperature

* Click 4 continuously: check valve opening

                                * Long press 3 seconds to enter the system menu

In the system menu, click is the switching of system

In other states, double-click to exit the current state parameters.

 
Radiator Thermostat A8

UP button / Enter key(In the system menu, enter a

parameter change for the first time

 

 

 

 

UP button / Enter key(In the system menu, enter a

parameter change for the first time



 
Radiator Thermostat A8
      Boost function

 

 

 

Working mode

The radiator thermostat has three work mode: automatic ( Auto) and manual (Manu) and holiday () In normal operation, you can press Mode/Menu button to select the work mode. From automatic to manual to holiday mode to automatic, cyclic replacement.If you want to maintain a fixed temperature for a certain period, e.g. during your holidays or a party, the holiday function can be used.

* Press the Mode/Menu button repeatedly, until the suitcase symbol () appears in the display. Using the UP or DOWN button to change the time and confirm by press the Mode/Menu button. Then set the end date and confirm by press the Mode/Menu button. Then set the temperature and confirm by press the Mode/Menu button and the display will flash to confirm.

* The set temperature will remain until the set end time. Afterwards, the radiator thermostat will switch back to auto mode.

 

Boost function

The boost function makes use of human sensations of heat. When activating the boost function, the heating valve is immediately opened to 80% for 5 minutes (factory setting). The heating of a room takes longer than 5 minutes, but the heat given off by the radiator can be felt immediately. If, for example, you arrive home earlier than usual or you need some extra heat in the morning in the bathroom, the boost function will help you to heat the room up quickly. 
Radiator Thermostat A8

* In normal operation, press the Mode/Menu and Down button at the same time, the remaining time for the function

will be counted down in seconds, display B299 to B000.

* After 5 minutes have elapsed, the actuator changes to the mode which was previously active (Auto/Manu) with the previously set temperature.

* The function can be deactivated prematurely at any time by double-click Mode/Menu button to exit.

* The boost function will not have an immediate effect if the radiator is covered of concealed (e.g. by sofa). The open-window function is deactivated while the boost function is active.

 

Child safeguard/opering lock

The operation of the device can be locked.

Radiator Thermostat A8

* In normal operation, to activate/deactivate the operating lock, press the UP and Down button at the same time

* After it has been activated, LOC appears in the display.

* To deactivate the operating lock, press both buttons again.

 

Calcification protection

 

To prevent calcification of the valve, the thermostat performs a rust removal operation at 12:00 every Saturday. During the period of rust removal, CAL appears in the display.

 

System Menu 

System menu is used to set system parameters. Press the Mode/Menu button for last 3 seconds,  appears in the display. This means you enter the system menu. Press the UP button for enter a parameter change for the first time and press the Mode/Menu button for goto next system parameter. System parameter sequence:

 

Radiator Thermostat A8

- Week program
 

- Set system year/month/day/hour/minute
 

- Display of valve position
 

- Open-window function
 

- Set calibration temperature
 

- Restoring the factory settings

 

 

 

Setting the week program

Set system year/month/day/hour/minute

Open-window function

Calibration temperature

Restoring the factory settings

These information you can saw the manule in the packing box, if you need details please sent E-mail  to ask the PDF manule 

Technical characteristics

Supply voltage:            2 x 1.5 V LR6/Mignon/AA

Current consumption:   100 mA (max.)

Battery life:                   3 years (typ.)

Degree of protection:   Ip20

Ambient temperature:   0 to 50

Surface temperature:    90 (at the radiator)

Connection:                   M30 x 1.5 mm

Linear travel:                  4.3 mm

Weight:                          180 g (incl. batteries)

Dimensions mm

Radiator Thermostat A8

 






FAQ

1. Can I request a sample order for a valve?

A: Certainly! We welcome sample orders to allow you to test and assess the quality of our products. We also accept mixed samples.

2. Is there a minimum order quantity (MOQ) for valve orders?

A: Yes, there is an MOQ. However, we have a low MOQ requirement. For specific quantity details, please contact us to negotiate.

3. How do I proceed with placing an order for a valve?

A: To begin, please inform us of your requirements or application. You can provide us with the item number, size, and desired order quantity. If the exact product is not available, you can provide us with a drawing.

Next, we will provide a quotation based on your requirements or offer our suggestions.

Once the price is confirmed, the customer can place a deposit for the formal order and confirm the sample if necessary.

Finally, we will arrange the production and delivery of the order.

4. Do you offer a guarantee for your products?

A: Yes, we provide a 3-year warranty for all our products.

5. What is your estimated delivery time?

A: The production time typically ranges from 35 to 45 days. However, if the samples need to be confirmed for the first time, the delivery time can be negotiated.
 