Differential Pressure Balancing Valve with Drainer Valve

Temperature: Low Temperature
Standard: En13828
Material: Brass
Type: Balance Valve
Transport Package: Carton
Specification: DN08 to DN 100
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Basic Info.

Model NO.
HTV-03023
Trademark
AIBOHOME
Origin
China
HS Code
848180
Production Capacity
8000000

Product Description

 
 

water balance control in heating andcooling system

5-25KPA pressure different controlvalve

HTV 03602 Adjustable static balance valvewith pressure measuring adapter

HTV 03602A Adjustable static balance valvewith drainer valve   

HTV 03602B Adjustable static balancevalve

HTV03023 Differential pressure balancing valves wishdrainer valve

HTV03023A Differential pressure balancing valves
Differential Pressure Balancing Valve with Drainer Valve

Description/Application

Differentialpressure balancing valves are used to achieve dynamic hydraulic balance inheating and cooling systems.

Themeaning of dynamic balance is: in a variable flow system, when the load changesfrom 0% to 100%, the system maintains a continuous balance by controlling thepressure change in the system. At the time of partial load, when the controlflow of the regulator is reduced, the pressure limit is still used to achievedynamic balance.

 

 

 

Maximum flow limited

The flow limiting function is achieved by combining the differentialpressure control valve HTV03023 with a configurable end valve. The flowlimiting function prevents end underflow and makes the pump work moreefficiently.

Reduced noise

Limiting the pressure difference at both ends of the regulatingvalve can avoid excessive pressure drop at both ends of the regulating valveunder partial load, and make the noise of the regulating valve under partialload less.

Do not need to balancedebugging

Flow limits are achieved by setting eachhydraulic loop as an independent loop that does not interact with each other sothat it only needs to be set once. No special balancing measures are needed.Can greatly save debugging costs.

 

technical specification

ITEM

DN

15-25

MAXMIUM   PRESSURE

BRA

16(PN16)

TEST   PRESSURE

BAR

25

VALVE   PRESSURE DIFFERENT

Kpa

10-150

Even   in the case of partial load, the maximum pressure difference at both ends of   the valve is not allowed to exceed 150Kpa

TEMPEREATURE   

ºC

-20---120

The   material that touches the water

Valve   body

Brass   CW617N

Stem   plug

Brass   CW602N (DZR)

Membrane

EPDM

Spring   

SUS   304


Differential Pressure Balancing Valve with Drainer Valve

Design

The HTV03023 is designed to maintain aconstant set pressure difference. The pressure of the return pipe acts on thelower volume of the control diaphragm, while the pressure difference of thewater supply acts on the upper side of the diaphragm through the pulse tube.The set pressure difference is maintained by the internal structure and theadjustment spring

Factorysetting 10Kpa
Differential Pressure Balancing Valve with Drainer Valve

Type selection

We recommend using Figure6 toselect the diameter of the differential pressure balancing valve. The maximumflow rate is calculated according to the valve pressure difference of 10KPa,which ensures the efficient use of the pump and saves energy.

For example:

Known: pipe flow 200L/h, pipe diameter DN15Result: At the vertical axis flow 200L/h, make a horizontal line to the right,intersect with the bar chart, select DN15 valve.

The relationship between valve size andpipe size

The Kv value of each specification isdetermined based on a flow rate range of up to 0.8m/s at 10KPa valvedifferential pressure. As long as the flow rate of water in the pipe is between0.3 and 0.8 m/s, the valve size should be equal to the pipe size.
other more application details please sent e-mail to take the detils, and HTV03602 is the patner valve with HTV03023, in FIGURE5 you will find the balance valve KVS and choose the selection click the number or picture to go to check the balance valve 